PVD02 Pressure plug, IP55

The pressure compensation plug equalises the pressure that occurs, due to temperature differences, inside the enclosure with the outside environment, while reducing the risk of dust entering the enclosure.

PVD Product Image
Characteristics  
Weight (kg) 0.10
PVD Catalogue drawing image
Item no.: PVD02
EAN no.: 8713574091443
  • Technical data
  • Features
  • Downloads

Technical data

Description:

It gives a controlled change in pressure. In the enclosures pressure differentials can occur during extreme temperature variations, when this happens there is risk of dust and humidity inside the enclosure. Mounting with a PG29 thread with nut, recommended torque of 5 Nm (max. 10 Nm). For optimal pressure compensation we recommend to use two devices on opposite sides towards the top of the enclosure. Sealing gasket NBR. Weather proof and UV light resistant according to UL746(f1). Air interface of approximately of 1.5 cm².

Material:

Plastic according to UL94 V-0. Sealing gasket NBR.

Operating temperature:

-45 to +70°C.

Machining required:

Round hole 37 mm diameter.

Protection:

IP 55.

Finish:

Light grey.

Pack quantity:

2 pieces.

Features

Feature:

Plastic pressure compensation plug with waterproof membrane.

Advantage:

In certain locations there can be wide temperature variations especially over a short period of time, which creates pressure differences from inside to outside of the enclosure. The pressure plug equalises the pressure inside and outside the enclosure allowing air and humidity to leave, while only allowing dry air to enter inside the enclosure. The plug can be easily installed and only requires a round hole to be machined.

Benefit:

The pressure compensation plug reduces the risk of dust entering the enclosure, ensuring that a vacuum is not created. Built up humidity can leave the enclosure which reduces potential hazards with electrical components. The ease of installation reduces the labour time required and means that the modification can be done on site while the enclosure is operational, saving unnecessary downtime.

Comment:

Highly recommended to install two plugs per enclosure for optimal pressure compensation. The plugs should be both be installed at the top of the enclosure but on opposite sides. If a higher protection degree is required, then the compensation pressure plug, EDA/EDAS, should be installed.

CAD 2D drawing (DXF) PVD02 329 KB
CAD 2D drawing (PDF) PVD02 211 KB
CAD 3D drawing (STEP) PVD02 1 MB
Image (JPG 800 x 518 px) PVD Catalogue drawing image 69 KB
Image (JPG 600 x 600 px) PVD Product Image 66 KB
Item sheet (PDF) PVD02 ENGLISH 61 KB
Mounting instructions document (PDF) Thermal Management PVD 237 KB
Product sheet (PDF) PVD 57 KB