MPC101R5 Top console, 500x1000x494

This mild steel combinable console system, MPC, has a IP 55/56 protection degree. It includes three interchangeable sections, top, desk and bottom. The system is very flexible and the various possible combinations can meet many design requirements. The ergonomic design of the top and desk units allows for easy installation and access to HMI-equipment, and increases the mounting space available. Stainless steel panels may be used as an alternative for some parts of the console, should it be exposed to chemical agents, etc.

CE Declaration of Conformity CSA GOST Kema Keur - DEKRA Lloyd's Register cULus_UL Listed IEC 61439 Declaration of Compliance
Feature: IP 66 TYPE 4, 12, 13 IK 10 (single door); IP 55 TYPE 12, 13 IK 10 (double door)
MPC Product Image
Characteristics  
Note Top section units, Mild steel
Height 500 mm
Width 1000 mm
Depth 494 mm
Weight (kg) 37.05
MPC - MPCS Catalogue drawing image
Item no.: MPC101R5
EAN no.: 8713574128149
  • Technical data
  • Features
  • Downloads
  • Certificates

Technical data

Material:

Body and door: 1.5 mm mild steel. Rear panel: 1.5 mm mild steel. Bottom plates: 1.2 mm galvanized steel. Mounting plate: 2.5 mm galvanized steel.

Body:

Folded and seam welded. Console construction counts with a base that provides a distance between the fl oor and the lower part of the door/s acting as an integrated plinth.

Doors and panels:

Single folded surface mounted with hinges allowing left and right-hand opening to base door. Top section and desk panels held open by self engage/self release mechanical panel stays. Concealed hinges allowing 90° opening on the desk. Double door on 1200 and 1600 mm wide base units.

Mounting plate:

Standard mounting plate in base unit. Fixed by fixing brackets on C rail, top and bottom for depth adjustment. Optional in desk and top section units.

Lock:

Double-bit 3 mm locks for top section and desk unit. For base, two double-bit 3 mm locks. Other options available. See wall mounting section.

Cable access:

Bottom opening in base unit for cable access. Bottom plates for cable glanding supplied as standard.

Earthing:

M8 threaded studs on bodies, doors and rear panels.

Finish:

RAL 7035 structured powder coating.

Protection:

Single door: IP 66 | TYPE 4, 12, 13 | IK 10. Double door: IP 55 | TYPE 12, 13 | IK 10.

Approvals:

CE, CSA, GOST, Kema Keur - DEKRA, Lloyd's Register, cULus_UL Listed.

Delivery:

The base unit is provided with a mounting plate as standard. Desk and top section units have mounting plates provided as accessories. All top and base openings can be closed by choosing the appropriate accessory plate. Suitable nuts and washers for the various earthing studs are provided.

Features

Feature:

Mild steel combinable console, available in three separate sections, with a IP 55/66 protection degree.

Advantage:

A flexible solution where customers can choose the console sections that meet their size and design requirements, off the shelf, in order to create the console configuration required for their application. Each standalone console section will maintain the security and protection degree.

Benefit:

Customers can receive consoles with a short delivery time, that match their size requirements. The ergonomic design of the top and desk unit, lets customers install and access HMI equipment easily, which increases the console's available mounting space. Component failure and unnecessary downtime is avoided as water and dust are prevented from entering the enclosure.

Comment:

Stainless steel top section panel (MPPS), and desk unit panel (MPLS) are available as accessories. Console desk and top sections are normally heavily used, due to the installed control components. Therefore, It is recommended to replace the panels on mild steel console, that are exposed to high levels of use, with stainless steel panels. Replacing mild steel sections for stainless steel prolongs the console's life as they are more resistant to corrosion. This is especially important in industries where the operators are exposed to chemical agents and could easily transfer them onto the console, when operated. Single door consoles have a IP66 protection degree whereas double door consoles have a IP55 protection degree.

CAD 2D drawing (DXF) MPC101R5 1 MB
CAD 2D drawing (PDF) MPC101R5 103 KB
CAD 3D drawing (STEP) MPC101R5 6 MB
Image (JPG 594 x 800 px) MPC - MPCS Catalogue drawing image 119 KB
Image (JPG 600 x 600 px) MPC Product Image 77 KB
Item sheet (PDF) MPC101R5 ENGLISH 303 KB
Mounting instructions document (PDF) HMI MPC-MPCS 768 KB
Product sheet (PDF) MPC 132 KB
Document (PDF) CE Declaration of Conformity 145 KB
Document (PDF) CSA 736 KB
Document (PDF) GOST 209 KB
Document (PDF) Kema Keur - DEKRA 769 KB
Document (PDF) Lloyd's Register 481 KB
Document (PDF) cULus_UL Listed 427 KB
Document (PDF) IEC 61439 Declaration of Compliance 45 KB