T-Series outdoor air conditioner T-Series outdoor air conditioner

The T-Series air conditioner is designed for outdoor environments. The unit is tested for IP56 and comes in a surface-coated galvanized sheet-metal cover for rugged factory and outdoor environments. It is also available in a stainless-steel model, Type 304. The unit is available for a cooling capacity range of 300 W to 4000 W and an operating temperature range from -40 °C to 55 °C.

CE Declaration of Conformity Declaration of Compliance EAC cULus_UL Listed
Feature: IP56 TYPE 4, 4X
T-Series outdoor air conditioner Product Image
  • Item list
  • Technical data
  • Features
  • Downloads
  • Certificates

Item list

Item no. Description Height
(mm)
Width
(mm)
Depth
(mm)
Cooling capacity L35L35
(W)
Cooling capacity L55/L55
(W)
Power supply
(V/ph/Hz)
T150116G150 T-Series outdoor 235W,115V 400 191 160 278 240 115 / 1 / 50-60
T150126G150 T-Series outdoor 264W,230V 400.0 191 160 237/280 270/281 230 / 1 / 50-60
T200216G150 T-Series outdoor 586W,115V 508 254 251 571/645 586/637 115 / 1 / 50-60
T200226G150 T-Series outdoor 586W,230V 508.0 254 251 571/645 586/637 230 / 1 / 50-60
T290416G150 T-Series outdoor 1172W,115V 737.0 432 287 1025/1143 1157/1245 115 / 1 / 50-60
T290426G150 T-Series outdoor 1172W,230V 737.0 432 287 1025/1143 1157/1245 230 / 1 / 50-60
T430616G150 T-Series outdoor 1958W,115V 1092.0 400 279 1611/1729 1857/1957 115 / 1 / 50-60
T430626G150 T-Series outdoor 1985W,230V 1092.0 400 279 1600/1713 1910/1985 230 / 1 / 50-60
T430826G150 T-Series outdoor 2400W,230V 1092.0 400 279 1740/1965 2193/2407 230 / 1 / 50-60
T430816G150 T-Series outdoor 2500W,115V 1092.0 400 279 1875/2080 2326/2528 115 / 1 / 50-60
T431016G150 T-Series outdoor 3016W,115V 1092.0 400 279 2245/2460 2832/3015 115 / 1 / 50-60
T431026G150 T-Series outdoor 3075W,230V 1092.0 400 279 2478/2589 2941/3126 230 / 1 / 50-60
T501226G150 T-Series outdoor 3516W,230V 1270.0 483 281 2725/2945 2939/3516 230 / 1 / 50-60
T531926G150 T-Series outdoor 5978W,230V 1346.0 533 330 4640/5300 5418/5987 230 / 1 / 50-60
T150116G152 T-Series outdoor-SS 235W,115V 400.0 191 160 278 240 115 / 1 / 50-60
T150126G104 T-Series outdoor-SS 264W,230V 400.0 191 160 237/280 270/281 230 / 1 / 50-60
T200216G155 T-Series outdoor-SS 586W,115V 508.0 254 251 571/645 586/637 115 / 1 / 50-60
T200226G103 T-Series outdoor-SS 586W,230V 508.0 254 251 571/645 586/637 230 / 1 / 50-60
T290416G159 T-Series outdoor-SS 1172W,115V 737.0 432 287 1025/1143 1157/1245 115 / 1 / 50-60
T290426G161 T-Series outdoor-SS 1172W,230V 737.0 432 287 1025/1143 1157/1245 230 / 1 / 50-60
T430616G102 T-Series outdoor-SS 1958W,115V 1092.0 400 279 1611/1729 1857/1957 115 / 1 / 50-60
T430626G159 T-Series outdoor-SS 1985W,230V 1092.0 400 279 1600/1713 1910/1985 230 / 1 / 50-60
T430826G108 T-Series outdoor-SS 2400W,230V 1092.0 400 279 1740/1965 2193/2407 230 / 1 / 50-60
T430816G153 T-Series outdoor-SS 2500W,115V 1092.0 400 279 1875/2080 2326/2528 115 / 1 / 50-60
T431016G102 T-Series outdoor-SS 3016W,115V 1092.0 400 279 2245/2460 2832/3015 115 / 1 / 50-60
T431026G104 T-Series outdoor-SS 3075W,230V 1092.0 400 279 2478/2589 2941/3126 230 / 1 / 50-60
T501226G125 T-Series outdoor-SS 3516W,230V 1270.0 483 281 2725/2945 2939/3516 230 / 1 / 50-60
T531926G109 T-Series outdoor-SS 5978W,230V 1346.0 533 330 4640/5300 5418/5987 230 / 1 / 50-60

*Items are manfucatured from stainless steel

Technical data

Description:

The T-Series outdoor air conditioner has a proven robust design for rugged environments. All standard models are equipped with head pressure control for low ambient operation, compressor heater, coated condenser coil, malfunction switch, thermostat and heater package. The unit is designed for a compact footprint and equipped with easy-mount flanges for simple installation. It is delivered with a cleanable, reusable aluminium mesh filter. Non stainless steel versions are equipped with a heater as standard. All units are equipped with a reliable mechanical thermostat for mounting on the side of an enclosure. Factory thermostat setting for cooler is 27 °C . The factory setting for heater is 13 °C.

Type of connection:

1,8 Meter cord with NEMA 5-15 plug.

Material:

Galvanized steel powder coated or Stainless steel.

Temperature limits inside:

+20 °C ... +55 °C.

Temperature limits outside:

-40 °C ... +55 °C.

Protection:

IP56 | TYPE 4X.

Finish:

RAL 7035 light-grey, semi-textured powder-coat paint standard. SS version is not painted.

Features

Feature:

Vertical cooling unit in a reliable robust design, available in a wide range of sizes for different cooling capacities, with IP 56 protection degree.

Advantage:

A unit that best meets cooling requirements can be easily selected. Easy-mount flanges for simple installation. Wide operating temperature range –40 °C to 55 °C.

Benefit:

Standard models are equipped with head pressure control for low ambient operation, compressor heater, coated condenser coil, malfunction switch, thermostat and heater package.

Comment:

To minimise energy consumption of the cooling unit, it is recommended to install a door switch, DSW01. The door switch will turn the cooling unit off when the door is opened.

Image (JPG 800 x 800 px) T-Series outdoor air conditioner Product Image 53 KB
Mounting instructions document (PDF) T-Series outdoor air conditioner - T15 483 KB
Mounting instructions document (PDF) T-Series outdoor air conditioner - T20 767 KB
Mounting instructions document (PDF) T-Series outdoor air conditioner - T29 1012 KB
Mounting instructions document (PDF) T-Series outdoor air conditioner - T43 865 KB
Mounting instructions document (PDF) T-Series outdoor air conditioner - T50 1 MB
Mounting instructions document (PDF) T-Series outdoor air conditioner - T53 1 MB
Product sheet (PDF) T-Series outdoor air conditioner(RUSSIAN) 121 KB
CE Declaration of Conformity
Document (PDF) Declaration of Compliance 77 KB
Document (PDF) EAC 2 MB
cULus_UL Listed