MCS-OG Oil and gas, mild steel combinable version, single door enclosure

The mild steel single door combinable floor standing enclosure range, MCS-OG, with a IP 56 protection degree, is available off the shelf in many different sizes and configurations. This enclosure range is well suited for many different applications within Oil and Gas market. The risk for component failure, and with that unnecessary downtime, is eliminated as water and dust are prevented from entering the enclosure.

CE Declaration of Conformity CSA DNV-GL EAC GOST Kema Keur - DEKRA Lloyd's Register Russian Maritime Register of Shipping cULus_UL Listed IEC 61439 Declaration of Compliance
Feature: IP 56 TYPE 4, 12, 13 IK 10
MCS Web Product Image
MCS Catalogue drawing imageMCS Catalogue drawing image
  • Item list
  • Technical data
  • Downloads
  • Certificates

Item list

With mounting plate

Item no. Description Height
(mm)
Width
(mm)
Depth
(mm)
Mounting Plate
Height
(mm)
Mounting Plate
Width
(mm)
Max. enclosure
useful depth
MCS20068R5 Floor standing, 2000x600x800 2000 600 800 1894 494 759
MCS20084R5 Floor standing, 2000x800x400 2000 800 400 1894 694 359
MCS20086R5 Floor standing, 2000x800x600 2000 800 600 1894 694 559
MCS20088R5 Floor standing, 2000x800x800 2000 800 800 1894 694 759

The enclosure with rear door, includes two mounting plates assembled back to back and four bottom plates.

Without mounting plate

Item no. Description Height
(mm)
Width
(mm)
Depth
(mm)
Mounting Plate
Height
(mm)
Mounting Plate
Width
(mm)
Max. enclosure
useful depth
MCS20068PER5 Floor standing, 2000x600x800 2000 600 800
MCS20084PER5 Floor standing, 2000x800x400 2000 800 400
MCS20086PER5 Floor standing, 2000x800x600 2000 800 600
MCS20088PER5 Floor standing, 2000x800x800 2000 800 800

The enclosure with rear door, includes two mounting plates assembled back to back and four bottom plates.

With mounting plate and rear door

Item no. Description Height
(mm)
Width
(mm)
Depth
(mm)
Mounting Plate
Height
(mm)
Mounting Plate
Width
(mm)
Max. enclosure
useful depth
MCS20068RDR5 Floor Standing, 2000x600x800 2000 600 800
MCS20086RDR5 Floor Standing, 2000x800x600 2000 800 600
MCS20088RDR5 Floor Standing, 2000x800x800 2000 800 800
MCS200810RDR5 Floor Standing, 2000x800x1000 2000 800 1000
MCS20108RDR5 Floor Standing, 2000x1000x800 2000 1000 800

The enclosure with rear door, includes two mounting plates assembled back to back and four bottom plates.

Without mounting plate and with rear door

Item no. Description Height
(mm)
Width
(mm)
Depth
(mm)
Mounting Plate
Height
(mm)
Mounting Plate
Width
(mm)
Max. enclosure
useful depth
MCS20068PERDR5 Floor Standing, 2000x600x800 2000 600 800

The enclosure with rear door, includes two mounting plates assembled back to back and four bottom plates.

Technical data

Material:

Frame: 1.5 mm painted steel. Door: 2 mm painted steel. Rear, roof and side panels: 1.5 mm painted steel. Mounting plate: 3 mm galvanized steel. Bottom plates: 1 mm galvanized steel.

Frame:

Seam welded reversed open profiles with 25 mm hole pattern according to DIN 43660. Including integrated external hole pattern.

Door:

Mounted with four hinges allowing left or right hand opening. Including door frame with 25 mm hole pattern.

Rear:

Enclosure with Rear panel fitted by M6 torx screws. Enclosure with Rear door instead of rear panel.

Side panels:

Supplied as an accessory.

Roof panel:

Removable.

Lock:

Espagnolette 4-point locking system. Does not interfere with the enclosure inner space. Standard double-bit lock with 3 mm insert. Standard inserts, cylinders, lift handles and T-handles are available as accessories.

Bottom plates:

Consists of three or four pieces for enclosures with one mounting plate and four or six for enclosures with two mounting plates mounted back to back.

Mounting plate:

Double folded and slides into position. Adjustable in depth by steps of 25 mm with the MPD02 accessory. Supplied outside of the enclosure packaging.

Earthing:

All panels are earthed through their fittings and are equipped with a separate earthing stud.

Finish:

RAL 7035 structured powder coating.

Protection:

Complies with IP 56 | TYPE 4, 12, 13 | IK 10.

Approvals:

CE, CSA, DNV-GL, EAC, GOST, Kema Keur, Lloyds shipping, RS, cULus_listed.

Mounting requirement:

Standard delivery ready for combined installation. For stand-alone installation add side panels.

Delivery:

Frame with fitted door, rear panel or rear door, roof panel, bottom plates, mounting plate and door frame. Delivery also includes earthing bolts. Delivered on a pallet which is identical to the width of the enclosure to allow suiting without removal. All packing material is recyclable.

Image (JPG 591 x 800 px) MCS Catalogue drawing image 131 KB
Image (JPG 587 x 800 px) MCS Catalogue drawing image 130 KB
Image (JPG 600 x 600 px) MCS Web Product Image 108 KB
Mounting instructions document (PDF) Floor standing combinable and compact 47 MB
Template (PDF) New locking system - Label template 108 KB
Document (PDF) CE Declaration of Conformity 62 KB
Document (PDF) CSA 251 KB
Document (PDF) DNV-GL 368 KB
EAC
Document (PDF) GOST 514 KB
Document (PDF) Kema Keur - DEKRA 275 KB
Document (PDF) Lloyd's Register 465 KB
Document (PDF) Russian Maritime Register of Shipping 617 KB
Document (PDF) cULus_UL Listed 427 KB
Document (PDF) IEC 61439 Declaration of Compliance 82 KB