EGK Anti condensation small heater

This small anti-condensation heater, EGK, is available with a heating capacity range of 10-30 watts. Its size makes it easy to also in tight spaces. Water condensation is eliminated, also when the ambient temperature drops sharply.

cULus_UL Listed
Feature: IP 44
EGK Product Image
EGK Catalogue drawing image
  • Item list
  • Accessories
  • Technical data
  • Features
  • Downloads
  • Certificates

Item list

Item no. Description Capacity
(W)
L
(mm)
Voltage
(V)
Starting current
(A)
Weight
(kg)
EGK010 Heater 10W 10 52 120-240V AC/DC 1.0 0.15
EGK020 Heater 20W 20 60 120-240V AC/DC 2.5 0.15
EGK030 Heater 30W 30 70 120-240V AC/DC 3.0 0.15

* The min / max voltage values for 120-240 V heaters are 110 / 265 V, operating with voltages below 140 V AC/DC reduces heating performance by approx. 10%.

Range Mandatory Accessories Related Accessories Similar accessories Description
ETR - - Adjustable temperature thermostat with either a normally open (NO) or normally closed (NC) contact
EFR - - Fixed temperature thermostat with either a normally open (NO) or normally closed (NC) contact

Technical data

Description:

Small semiconductor heater to be fixed in vertical position to prevent condensation. Mounting clip for 35 mm DIN rail (EN60715).

Heating element:

PTC resistor, self regulating and temperature limiting.

Material:

Plastic, and anodised aluminium profile.

Operating temperature:

-45 to +70°C. The heating capacity is for ambient temperature 20ºC.

Connection:

3x0.5 mm² (300 mm) silicon cable. For UL heaters 3XAWG20 (300 mm) cable.

Protection:

IP 44, Class I (earthed).

Approvals:

CE, EAC, cULus_UL Listed.

Pack quantity:

1 piece.

Features

Feature:

Anti-condensation small heater, available in a range of heating capacities.

Advantage:

The heater is available in different capacities from 10-30 watts. As it is small in size, the heater can be installed in tight spaces that have low heating requirements.

Benefit:

When installed, water condensation will be avoided especially in situations when the ambient temperature dramatically drops. Due to its low heating capacities, the heater can be installed in enclosures that have limited available space.

Comment:

A thermostat with a normally closed contact, ETR or EFR, is recommended in order to control the heater.

Image (JPG 800 x 470 px) EGK Catalogue drawing image 35 KB
Image (JPG 600 x 600 px) EGK Product Image 138 KB
Mounting instructions document (PDF) Thermal Management EGK 225 KB
Product sheet (PDF) EGK 103 KB
Document (PDF) cULus_UL Listed 74 KB